Loading...
Performance assessment of an integrated absorption cooling-hydrogen liquefaction system using geothermal energy
Gadalla, Mohamed ; Ratlamwala, Tahir Abdul Hussain ; Dincer, Ibrahim ; Kanoglu, Mehmet
Gadalla, Mohamed
Ratlamwala, Tahir Abdul Hussain
Dincer, Ibrahim
Kanoglu, Mehmet
Date
2013
Advisor
Type
Article
Degree
Citations
Altmetric:
Description
Abstract
An integrated geothermal based triple effect absorption cooling and Linde-Hampson system for hydrogen gas liquefaction is proposed and analysed thermodynamically. The effect of various operating conditions and parameters on the system performance is studied. The results show that the mass of hydrogen gas pre-cooled by the absorption system per unit mass flow rate of geothermal water flowing through the system (n) and the amount of hydrogen liquefied per unit mass flow rate of geothermal water flowing through the system (y) increase with an increase in the geothermal source temperature. Also, both energetic and exergetic coefficients of performance decrease from 1.33 to 0.12 and 0.92 to 0.08, respectively with an increase in the mass flow rate of geothermal water from 1.5 kg/s to 3.0 kg/s. The energetic and exergetic utilisation factors decrease from 0.06 to 0.009 and 0.19 to 0.006, respectively as the mass flow rate of geothermal water increases.